Repair and water – proofing mix in-depth TD 5745 – 001 – 54575429 - 2008
Basic Technical Data
Directions for use1. The surface pre - treatment.The surface pre - treatment involves cleaning, washing and wetting operations. The surface under repairing is to be thoroughly cleaned from dirt, grease, paint or foreign coatings. A loose fractured concrete layer is peeled to a monolith base. This surface treatment provides the access of reactive chemicals of Antigidron to the pores and capillary tracks of a mineral structure. To waterproof the cracks and joints in the concrete, rock, brick building structures it is necessary to cut an additional (20 x 20 mm section) slit right along the crack (joint) by a pick hammer (slitting tool or a metal saw, etc.). Note:
A careful material selection and the way of water - proofing should be specially observed if the water pressure exerts an effect on the crack from the inside of the concrete. For this case, particularly, the membrane (smearing) water – proofing is unsuitable since it, unlike the sealing and water – proofing in – depth, is unable to work for “breaking – off”. Remember: it is impossible to waterproof the surface safely if the cracks being unbraced or unsealed. The cracks treated on the surface solely, then the cracks can be inevitably opened to cancel the water - proofing work completely. The surface is either washed or peeled by scrubbers, brushes or by air-jet to remove totally all the residual products after cleaning operations (exclusive attention should be paid to the seams, joints and cracks). Then the surface is damped until it is fully saturated (surface stops water imbibing). The surface is considered to be treated if it has been peeled till the monolith base, it is dust - free and enough damped. 2. The mix preparation.To prepare the mix for repair water - proofing purpose the Antigidron powder Mark VL50, in a quantity suitable for the consumption within 45 minutes since the water addition, is to be filled in two steps with drinking water while stirring in the total water/ Antigidron ratio of 0.17 – 0.23 l water to 1 kg powder. At first a minimum quantity of water is added and then the mix is stirred to obtain a homogeneous mass. Then the mix is set for 3 - 5 min. and stirred once more to obtain a working consistence of the mix, the water is added “if necessary”, but its quantity should not exceed the water/Antigidron ratio prescribed above. Note:
The Antigidron Mark VL50 can be prepared either manually or mechanically.
3. The mix smearing over the surfaceAntigidron Mark VL50 should be smeared on the surface to be repaired by a flexible spittle, trowel or mechanically. The thickness of this repair water - proofing layer is to 5 mm of grid - free. A small tolerance for the thickness of the layer smeared for flattering the rough surface is admissible. The mix has been smeared, the surface treated should be set under humid condition for 3 days not less and if the humidity is not less 90%, the surface should be covered with polyethylene, tarpaulin, etc. or should be periodically from time to time spray - moistened. The finishing works on the surface treated by a water - proofing mix should be carried out not earlier than 14 days later since the mix was applied. 4. The mix slit sealingThe slit treated, as prescribed above is filled with Antigidron Mark VL50 by a spattle, trowel or mechanically to ensure an air - proof adjoining of the latter to the slit surface. The consumption of the slit filled with Antigidron VL50 is 1,9 kg/dm2 for a slit. For the slit of 20 x 20 mm section the consumption of Antigidron Mark VL50 is 0,8 kg /m length. One can start treating the surface adjoining the slit filled with not earlier than 16 hours after the slit is to be filled with the Antigidron Mark VL50. To repair, if necessary, the surface slits filed with the Antigidron Mark VL50, using plaster cement mortars, one can start working not earlier than 2 days later. To paint, if necessary, the surface slits filled with the Antigidron Mark VL50 one can start working not earlier than 15 days later. WARNINGS
When workings with the mix one should observe the safety precautions for plastering works on cement-sand mortars base:
|
|||||||||||||||